Major change:
- added struct that contains upper/lower loop limits for the CC and FC variables
- face centered variables are now stored on the x- faces instead of the x+
- fixed multiple problems with the advection operator that showed up in both
symmetric converging and diverging velocity fields.
To do: Something is not quite right with the 2nd order version of the
advection operator. The shock tube results look like smooth first order results.
0 lines of code changed in 16 files:
turn off Godunov sonic approximation in the face centered velocities
1 lines of code changed in 1 file:
This version is readable.
0 lines of code changed in 2 files: